Registry / Framework

framework · v0.1.2
Gauge Hysteresis
Raise and clear a flood-gauge advisory with a lower reset band using integer level units.
Use Gauge Hysteresis
use vendor::gauge_hysteresis::gauge_hysteresis;
Run the example
nest demo gauge_hysteresis@0.1.2
blyxc native-run gauge_hysteresis-demo/main.blyx
Example source and expected output
use std::cli;
use std::text;
use vendor::gauge_hysteresis::gauge_hysteresis;
fn main() {
let arguments = cli_args();
if args_len(arguments) > 0 {
if args_len(arguments) % 2 != 0 {
stderr_line("Expected event and value pairs");
process_exit(2);
}
let mut live = gauge_hysteresis_start();
let mut i = 0;
while i < args_len(arguments) {
let input = args_at(arguments, i + 1);
if !text_is_number(input) {
stderr_line("Expected a whole numeric event value");
process_exit(2);
}
live = gauge_hysteresis_step(live, args_at(arguments, i), text_number(input));
let command = gauge_hysteresis_command(live);
println!(command);
if command == "reject" { process_exit(1); }
i += 2;
}
return;
}
let mut state = gauge_hysteresis_start();
state = gauge_hysteresis_step(state, "set", 12.0);
println!(gauge_hysteresis_command(state));
state = gauge_hysteresis_step(state, "level", 12.0);
println!(gauge_hysteresis_command(state));
state = gauge_hysteresis_step(state, "level", 11.0);
println!(gauge_hysteresis_command(state));
state = gauge_hysteresis_step(state, "level", 10.0);
println!(gauge_hysteresis_command(state));
}
Expected output
set_rise_level
announce_high
retain_advisory
announce_clear
Published versions
| Version | Package | Source commit | SHA-256 |
|---|---|---|---|
| 0.1.2 | Download ZIP · Browse files | 15024804c2 | 73b58d8356196c41748a37a44c93ec0a5b614c4139c59ade87e5ff1e90b2f693 |
| 0.1.1 | Download ZIP · Browse files | f84f6aa5fd | 560a90e824c0d630746548568ea601d8b951e0d895f67b0832d43cedd4b26745 |
| 0.1.0 | Download ZIP · Browse files | 6349f23784 | b9c227f8988fb6ca6e0bb1fa99990c40d16066e588848391a4dcdcc157e4db90 |